YYoouurr ssaaffeettyy aanndd tthhee ssaaffeettyy ooff ootthheerrss
iiss vveerryy iimmppoorrttaanntt..
We have provided many important safety
messages in this manual and on your
appliance. Always read and obey all
safety messages.
This is the safety alert symbol. This
symbol alerts you to hazards that
can kill or hurt you and others.
All safety messages will be
preceded by the safety alert symbol and
the word “DANGER” or “WARNING”.
These words mean:
YYoouu wwiillll bbee kkiilllleedd oorr sseerriioouussllyy iinnjjuurre
edd iiff yyoouu
ddoonntt ffoollllooww iinnssttrruuccttiioonnss..
YYoouu ccaann bbee kkiilllleedd oorr sseerriioouussllyy iinnjjuurreedd iiff
yyoouu ddoonntt ffoollllooww iinnssttr
ruuccttiioonnss..
All safety messages will identify the
hazard, tell you how to reduce the chance
if injury, and tell you what can happen if
the instructions are not followed.
INSTALLATION
INSTRUCTIONS
BUILT-IN BOTTOM MOUNT REFRIGERATOR/FREEZER
Retain for Future Reference
VIKING RANGE CORPORATION
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
IMPORTANT - PLEASE READ AND FOLLOW
Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying voltage, frequency, wattage,
amperage, and phase is attached to the product.
To reduce the risk of fire, electric shock, or injury to persons, installation work and electrical wiring must be done by qualified
people in accordance with all applicable codes and standards, including fire-rated construction.
The installer should leave these instructions with the consumer who should retain them for local inspector’s use and for
future reference.
GENERAL INFORMATION
It is your responsibility to :
-comply with installation specifications and dimensions
-properly install unit
-remove any moldings or decorative panels that prevent the unit from being
serviced
-make sure that you have these materials (not provided with your unit),
which are necessary for proper installation:
1/4” (6 mm) copper tubing with shutoff valve
6 - #8 x 3” (7.6 cm) wood screws (Longer screws may be required.)
1 - Saddle valve (Do not use self-piercing feature of the valve)
-assure that floor will support unit, door panels and contents
(approximately 1200 pounds [540 kg])
-provide a properly grounded electrical outlet
-assure that location will permit appliance doors to open 90
o
minimum
TTIIPP OOVVEERR HHAAZZAARRDD
AApppplliiaannccee iiss ttoopp hheeaavvyy aanndd ttiippss eeaassiillyy
wwhheenn nnoott ccoommpplleetteellyy iinnssttaalllleedd..
KKeeeepp ddoooorrss ccllo
osseedd uunnttiill aapppplliiaannccee iiss
ccoommpplleetteellyy iinnssttaalllleedd aanndd sseeccuurreedd ppeerr
iinnssttaallllaattiioonn iinnssttrruuccttiioonnss..
UUssee ttwwoo oorr m
moorree ppeeooppllee ttoo mmoovvee aanndd
iinnssttaallll aapppplliiaannccee.. FFaaiilluurree ttoo ddoo ssoo ccaann
rreessuulltt iinn ddeeaatthh oorr sseerriioouuss iinnjjuurryy..
MMoosstt ooff tthhee uunniittss wweeiigghhtt iiss aatt tthhee
ttoopp.. EExxttrraa ccaarree iiss nneeeeddeedd wwhheenn
mmoovviinngg tthhee uunniitt ttoo pprreevveenntt ttiippppiin
ngg..
UUssee ccaarrddbbooaarrdd sshhiippppiinngg mmaatteerriiaall oorr
ppllyywwoooodd uunnddeerr uunniitt uunnttiill iitt iiss
iinnssttaalllleedd iinn tthhee ooppeerraattiinngg ppoossi
ittiioonn ttoo
pprrootteecctt fflloooorr ssuurrffaaccee..
WARNING
DANGER
WARNING
Seitenansicht 0
1 2 3 4 5 6 ... 35 36

Inhaltsverzeichnis

Seite 1 - INSTRUCTIONS

YYoouurr ssaaffeettyy aanndd tthhee ssaaffeettyy ooff ootthheerrssiiss vveerryy iimmppoorrttaanntt..We have provided many important safetymess

Seite 2

10DOOR SWING CONSIDERATIONSDESIGNER MODELFULL OVERLAY MODEL

Seite 3

11TIPPING CONSIDERATIONSPROFESSIONAL MODELSDESIGNER AND FULL OVERLAY MODELS82-5/8”(209.9 cm)86-1/16”(218.6 cm)

Seite 4 - FEATURES OF YOUR REFRIGERATOR

BOTTOM MOUNT REFRIGERATOR OVERALL DIMENSIONSPROFESSIONAL MODELSSSSSS35-1/2”(90.2 cm)22 3/16”(56.4 cm)24 3/4”(62.9 cm)5/16”(0.8 cm)9/32”(0.7 cm)11/32”(

Seite 5 - CABINET OPENING DIMENSIONS

13CABINET INFORMATION - PROFESSIONAL MODELSProfessional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door face protru

Seite 6

14CABINET INFORMATION - PROFESSIONAL MODELS (Cont’d)

Seite 7 - WATER SUPPLY REQUIREMENTS

15CUSTOM SIDE PANEL DIMENSIONS - PROFESSIONAL MODELSFOR 3/4" (1.9 cm) SIDE PANELS

Seite 8 - ELECTRICAL REQUIREMENTS

16BOTTOM MOUNT REFRIGERATOR OVERALL DIMENSIONSDESIGNER MODELSTTOOPPSSIIDDEE36” (91.5 cm)DDOOOORRFFRROONNTT36” (91.5 cm)35” (88.9 cm)

Seite 9

17CABINET AND PANEL INFORMATION - DESIGNER MODELSDesigner models fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the

Seite 10 - DOOR SWING CONSIDERATIONS

18CABINET AND PANEL INFORMATION - FULL OVERLAY MODELSFull overlay models, (with 3/4” [1.9 cm], thick panels and custom handles locally supplied), fit

Seite 11 - TIPPING CONSIDERATIONS

19CABINET AND PANEL INFORMATION - FULL OVERLAY MODELSFull overlay models, (with 3/4” [1.9 cm], thick panels and custom handles locally supplied), fit

Seite 12 - PROFESSIONAL MODEL

2BASIC SPECIFICATIONS AND DIMENSIONS - PROFESSIONAL MODELSDDEESSCCRRIIPPTTIIOONN VVCCBBBB336633Overall Width 36” (91.5 cm)Overall Height from Bottom M

Seite 13

20CABINET AND PANEL INFORMATION - FULL OVERLAY MODELS (Cont’d)Full overlay models can be installed in standard 24” (61.0 cm) deep openings. However,

Seite 14

21CUSTOM PANEL DIMENSIONS

Seite 15

22CUSTOM PANEL HINGE CUTOUT DETAILNOTE: Steps below show panel upside down and notched for a left hinge application. Overview of door and notchlocat

Seite 16 - DDOOOORR

23DOOR PANEL INSTALLATIONPanels must not weigh more than 50 pounds per door. Refer to “Custom Panel Dimensions” on page 21 for detailedpanel instruct

Seite 17 - (5.1 cm) curved handle depth

24“Z” BRACKET INSTALLATION

Seite 18 - 35” (88.9 cm)

25CUSTOM SIDE PANEL DIMENSIONSDESIGNER/FULL OVERLAY MODELSFFOORR 33//44”” ((11..99 ccmm)) SSIIDDEE PPAANNEELLSSNNOOTTEE:: AAddddiinngg aa 33

Seite 19

26CUSTOM FINISHING OPTIONSDoor ClearancesAll installations must allow for the refrigerator and freezer door to open a minimum of 90o.•For side wall or

Seite 20

27OPTIONAL CUSTOM AIR GRILLE DIMENSIONSOPTIONAL CUSTOM AIR GRILLE DUCT LIP EDGE LOCATIONSFFRROONNTT VVIIEEWW35-1/2” (90.2 cm)34” (86.4 cm)3/4” (1.9 c

Seite 21 - CUSTOM PANEL DIMENSIONS

28REAR VIEW DIMENSIONSTOP AND BOTTOM VIEW DIMENSIONSENDS DIMENSIONS32-3/16” (81.8 cm)34” (86.4 cm)30-27/32” (78.3 cm)5-17/32”(14.0 cm)4-11/64”(10.6 cm

Seite 22 - Figure A

29HINGE COVER DIMENSIONS1/2” (1.3 cm)3-1/8”(7.9 cm)1/4” (0.6 cm)26o23/32”(1.8 cm)Hinge cover protrudes 9/32” (0.7 cm) beyond wood grille35-1/2 (90.2 c

Seite 23 - DOOR PANEL INSTALLATION

3BASIC SPECIFICATIONS AND DIMENSIONS - FULL OVERLAY MODELSDDEESSCCRRIIPPTTIIOONN DDFFBBBB336633Overall Width 36” (91.5 cm)Overall Height from Bottom M

Seite 24 - “Z” BRACKET INSTALLATION

30MMoosstt ooff tthhee uunniitt’’ss wweeiigghhtt iiss aatt tthhee ttoopp.. EExxttrraa ccaarree iiss nneeeeddeedd wwhheenn mmoovviinngg

Seite 25 - DESIGNER/FULL OVERLAY MODELS

31SECURING THE UNIT (3 OPTIONS)OPTION 1If a solid soffit is 1” (2.5 cm) or less above the unit, anti-tip boards are not required.OPTION 2If a solid so

Seite 26 - CUSTOM FINISHING OPTIONS

32UNIT INSTALLATION (Cont’d)Before moving the unit in place, confirm the finished dimensions, electrical location, minimum door and shelfclearances, a

Seite 27 - (10.2 cm)

33WATER CONNECTION•Refer to water supply requirement section for preliminary installation and site preparation (see page7 ).••DDoo nnoott uussee pp

Seite 28 - ENDS DIMENSIONS

34Align the holes on both ends of the louvered panelwith the holes in the base of the unit.Adjust the kickplate to the desired height and fastenin pla

Seite 29 - INSERT DIMENSIONS

35WIRING DIAGRAMBUILT-IN 36” W. BOTTOM MOUNT REFRIGERATOR/FREEZERWWAARRNNIINNGG::EELLEECCTTRRIICCAALLGGRROOUUNNDDIINNGGIINNSSTTRRUUCCTTIIOONNSSThis ap

Seite 30 - UNIT INSTALLATION

VIKING RANGE CORPORATION111 Front Street • Greenwood, Mississippi 38930 USA • (662) 455-1200Specifications subject to change without noticeF20353(PS07

Seite 31 - SECURING THE UNIT (3 OPTIONS)

4FEATURES OF YOUR REFRIGERATOR1. Electronic Controls2. Spillproof Shelves (5)3. Moisture Control Produce Drawers (2)4. Meat SavorTM/Produce Drawer

Seite 32 - UNIT INSTALLATION (Cont’d)

5SITE PREPARATIONS AND CONSIDERATIONSPROFESSIONAL MODEL BOTTOM MOUNT REFRIGERATOR/FREEZER CABINET OPENING DIMENSIONS((22)) 22””xx44”” MMoouunnttiinn

Seite 33 - WATER CONNECTION

6SITE PREPARATIONS AND CONSIDERATIONSDESIGNER/FULL OVERLAY MODEL BOTTOM MOUNT REFRIGERATOR/FREEZER CABINET OPENING DIMENSIONS((11)) 22””xx44”” MMoou

Seite 34 - HINGE ADJUSTMENT

7WATER SUPPLY REQUIREMENTSEELLEECCTTRRIICCAALL SSHHOOCCKK HHAAZZAARRDDSSoommee wwaatteerr mmaayy rreemmaaiinn iinn lliinnee.. EElleeccttrrii

Seite 35 - WWAARRNNIINNGG::

8Plumbing DimensionsAA BB36” W. Professional 35 1/2” (90.2 cm) 24” (61.0 cm)36” W. Designer 36” (91.5 cm) 24” (61.0 cm)36” W. Full Overlay 36” (91.5 c

Seite 36 - (PS0705VR)

9Anti-Tip RequirementsThe anti-tip boards should be fastenedinto position prior to moving the unit intothe opening. Note: Additional mounting boards