A. Definitions
The AES-NET interface, included with the AES-2005, allows a local Wiegand device such as a Proximity Card Reader to
be added to the AES-2005 accessible door entry system. Using Proximity cards instead of keyless entry codes, the build-
ing manager keeps control over the number of people that can let themselves into the building. The Wiegand device used
may be the Viking model PRX-1 Proximity Card Reader or any other card reader, RF transmitter, or digital keypad that out-
puts 26 bit Wiegand data.
In addition to a directly connected Wiegand device, the AES-NET interface also provides two wire CAN bus connections
which supports up to 32 additional remote points of entry. Each additional remote entry point requires one Viking Model
ES-3 door controller, one Wiegand device, and a door strike or magnetic lock of your choice. Only one pair of wires are
needed to wire all 32 entry system door controllers back to the AES-NET interface.
Specifications:
Maximum CAN length: 0.8 Km (2600 ft) using 24 AWG twisted pair, 1.6 Km (5300 ft) using 2 pairs of 24 AWG twisted pair
Maximum Wiegand Length: 244m (800 ft) - 24 AWG wire
Connections: Six cage clamp screw terminals
B. Wiring
26 bit Wiegand format: The industry standard data output of access
control card readers.
CAN Communications: A highly reliable two wire communications
protocol developed for the automotive industry.
Entry point: A door or gate allowing access into a secure or con-
trolled area.
Proximity Card Reader: A device used to read the data from a
Proximity Card when it’s held within a few inches of the reader.
Facility Code: A 3-digit number that each proximity card contains in order
to provide greater security. Usually the cards used at a given building all
have the same facility code. By programming cards with different facility
codes, these cards can have access to certain doors. Using this feature,
the entry system can be set up for “zones”.
Proximity Card: A credit size card that identifies itself when within close
proximity of a reader. Card “swiping” is not necessary. The card contains a
3 digit Facility Code, a 5 digit Internal Card number and a 5 digit External
Printed number, that may or may not match the Internal number.
70200Q170200
W 0.5W100W 0.5W
J2
1
1
2
1
J12
1
J4
1
J10
1
2
1
10
J2
1
1
8
1
6
+
-
R12R12 R39R39
Local Card Reader
(Viking model PRX-1
shown, see DOD# 221
not included)
26 Bit Wiegand Data and Power
Two wire CAN
communication BUS
LH
White
Green
Red
Black
Up to 32 total
ES-3 Controllers
(not included)
S1
C
JP3JP2JP1JP5JP4JP6
CCCC
ENTRY SYSTEM
DOOR CONTROLLER
VIKING
ELECTRONICS
HUDSON, WI 54016
VIKING
©
MODEL ES-3
INPUTS
RELAY OUTPUTS
POWER
INPUT
WIEGAND
DEVICE
CAN
COMM
ENTRY LOCATION
GROUP
LO HI
STATUS LED
12-24V
AC or DC
REQUEST
TO EXIT
DOOR
SENSOR
RELAY
1
RELAY
2
RELAY
3
BLK RED GRN WHT
WEIGAND DEVICE
L H
CAN
S1
C
JP3JP2JP1JP5JP4JP6
CCCC
ENTRY SYSTEM
DOOR CONTROLLER
VIKING
ELECTRONICS
HUDSON, WI 54016
VIKING
©
MODEL ES-3
INPUTS
RELAY OUTPUTS
POWER
INPUT
WIEGAND
DEVICE
CAN
COMM
ENTRY LOCATION
GROUP
LO HI
STATUS LED
12-24V
AC or DC
REQUEST
TO EXIT
DOOR
SENSOR
RELAY
1
RELAY
2
RELAY
3
BLK RED GRN WHT
WEIGAND DEVICE
L H
CAN
S1
C
JP3JP2JP1JP5JP4JP6
CCCC
ENTRY SYSTEM
DOOR CONTROLLER
VIKING
ELECTRONICS
HUDSON, WI 54016
VIKING
©
MODEL ES-3
INPUTS
RELAY OUTPUTS
POWER
INPUT
WIEGAND
DEVICE
CAN
COMM
ENTRY LOCATION
GROUP
LO HI
STATUS LED
12-24V
AC or DC
REQUEST
TO EXIT
DOOR
SENSOR
RELAY
1
RELAY
2
RELAY
3
BLK RED GRN WHT
WEIGAND DEVICE
L H
CAN
Viking Model ES-3 shown, see DOD# 195, not included
Back view of
the AES-2005
AES-NET Interface
One local Wiegand device (typically a Proximity card reader) is fully supported (power and data) from the AES-NET
interface. Connect only the black, red, green and white wires as shown below. Keep unused leads insulated.
In addition the AES-NET interface allows the AES-2005 to communicate with the Viking model ES-3 entry system door
controller via a two wire CAN Communication Bus. CAN bus distances of up to 1/2 a mile (over 2600 feet) are achieved
using common 24 gauge CAT-2 through CAT-5 wire, and 1 mile (5280 feet) is possible by doubling up on the 24 gauge
twisted pair (or running at least 21 gauge) . Up to 32 ES-3 entry system door controllers may share the same CAN com-
munication pair. The CAN bus must be polarity correct, so that all CAN-H connections and all CAN-L connections are
common.
Also available, not shown:
PRX-2 Keypad / Card Reader
(DOD# 219)
PRX-3 Card Reader (DOD# 228)
PRX-4 Keypad (DOD# 199)