Viking ES-3 Bedienungsanleitung Seite 3

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 5
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 2
The ES-3 can be wired with either a normally open or a normally closed Door Sensor switch by setting the shunt locat-
ed directly behind the Door Sensor screw terminals to either Normally Open (NO), or Normally Closed (NC).
The ES-3 can be wired with either a normally open or a normally closed Request to exit device switch by setting the
shunt located directly behind the Request to Exit screw terminals to either Normally Open (NO), or Normally Closed
(NC).
Relay 2 can provide either a Normally Open (NO), or Normally Closed (NC) contacts to control a courtesy light, a
gate/door opener, a second door strike/magnetic lock, or start a camera. Use the shunt located directly behind the relay
screw terminals to set the normal state.
Relay 3 can provide either a Normally Open (NO), or Normally Closed (NC) contacts to trigger an alarm,activate a
security panel lamp, or start a camera. Use the shunt located directly behind the relay screw terminals to set the nor-
mal state.
- or -
- or -
D
0
1
2
3
4
5
8
6
7
9
A
B
C
E
F
C
JP3JP2JP1JP5JP4JP6
CCCC
1
ENTRY SYSTEM
DOOR CONTROLLER
VIKING
ELECTRONICS
HUDSON, WI 54016
VIKING
©
MODEL ES-3
INPUTS
RELAY OUTPUTS
POWER
INPUT
WIEGAND
DEVICE
CAN
COMM
ENTRY LOCATION
GROUP
LO HI
STATUS LED
12-24V
AC or DC
REQUEST
TO EXIT
DOOR
SENSOR
RELAY
1
RELAY
2
RELAY
3
BLK RED GRN WHT
WEIGAND DEVICE
L H
CAN
"Push to Open"
button, push bar
switch, or motion
sensor
Camera
Magnet
Door switch
- or -
- or -
- or -
Courtest
Lights
Gate/Door
Opener
Camera
Second
Door strike/
Magnet lock
Alarm
Panel
Security
Panel Lamp
Shunt Selections
Normally Open
- or -
Normally Closed
B. Advanced Features
Seitenansicht 2
1 2 3 4 5

Kommentare zu diesen Handbüchern

Keine Kommentare