Viking Range, LLC
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information,
call 1-888-(845-4641)
or visit the Viking Web site at vikingrange.com
F21339 EN
(123113)
Installation Guide
All Refrigerator/All Freezer
Seitenansicht 0
1 2 3 4 5 6 ... 23 24

Inhaltsverzeichnis

Seite 1 - Installation Guide

Viking Range, LLC111 Front StreetGreenwood, Mississippi 38930 USA(662) 455-1200For product information,call 1-888-(845-4641)or visit the Viking Web si

Seite 2 - Please Read and Follow!

Dimensions 1924”(61.0 cm)1”(2.54 cm)Between Units9–5/32”(23.3 cm)82–3/4”(210.2 cm)min.to84–1/16”(213.5 cm)max.20–3/4”(52.7 cm)23–3/8”(59.4 cm)75–15/16

Seite 3

Specifications 2124”(61.0 cm)1”(2.54 cm)Between units35”(88.9 cm)35”(88.9 cm)36”36”(91.5 cm)(91.5 cm)36”36”(91.5 cm)(91.5 cm)36”(91.5 cm)36”(91.5 cm)9

Seite 4

79–3/8”(201.6 cm) min.to bottom of anti-tip board80–1/2”(204.6 cm) max.to bottom of anti-tip boardOne 2”x 4” mounting board per unit1–1/2” (3.8 cm) x

Seite 5 - 75–15/16”

79–3/8”(201.6 cm) min.to bottom ofanti-tip board80–1/2”(204.6 cm) max.to bottom ofanti-tip boardNote: If unit is installed deeper than24” (61.0 cm), t

Seite 6

79–3/8”(201.6 cm) min.to bottom ofanti-tip board80–1/2”(204.6 cm) max.to bottom ofanti-tip boardNote: If unit is installed deeper than24” (61.0 cm), t

Seite 7

Top View1–13/16”(4.6 cm)Space if 24” (61.0 cm)standard cabinetdepth is usedDoor24”(61.0 cm) Standard cabinet depthWall3/4”(1.9 cm

Seite 8

Top ViewFlush mount cabinet doorsTop ViewOverlapping cabinet doorsDoor24”(61.0 cm)Standard cabinet depth24-3/4”(62.9 cm)Wall3/4”(1.9 cm)Full end panel

Seite 9

3/4”(1.9 cm)End panel1”(2.5 cm)1/4”(0.6 cm)Z-Bracket21-3/4”(55.2 cm)21-3/4”(55.2 cm)24”(61.0 cm)Optional kickplate notchDimensions determined by cabin

Seite 10 - Dimensions

3534General InformationWater Supply Requirements(All Freezer)Use only 1/4” (6 mm) copper tubing forwater line. Do Not install copper tubing inarea whe

Seite 11 - Specifications

3712Place unit in front of cutout.Pull the center grille louver up at an angle and pull out.34Using an 8” magnetic nut driver, remove the two 1/4” scr

Seite 12 - Water Line Entry Area

32Table of Contents IMPORTANT—Please Read and Follow!• Make sure that incoming voltage is the sameas unit rating. An electric rating platespecifying v

Seite 13 - (204.6 cm) max

3938Remove 4 side screws and remove unit top.Loosen the 4 hinge screws. Adjust door. Retighten 4 hinge screws.Replace unit top. Replace 4 side screws.

Seite 14 - Flush Mount only

4140Turn on water supply and check for leaks.Lift unit off rollers to desired height and level unit usinga 5/16” head wrench.Note: DO NOT use an elect

Seite 15 - Top View

Performance Checklist43□ Verify cabinet size.□ Verify electrical supply and water supply(if applicable).□ Install anti-tip device(s) and verify uni

Seite 16 - (With Flush Mount Trim)

45Service & RegistrationOnly authorized replacement parts may beused in performing service on the appliance.Do not repair or replace any part of t

Seite 18 - (All Freezer)

IMPORTANT—Please Read and Follow!5IMPORTANT—Please Read and Follow!4A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state

Seite 19 - Installation

724”(61.0 cm)35”(88.9 cm)75–15/16”(192.9 cm)3–19/32”(9.1 cm))36”36”(91.5 cm)(91.5 cm)36”(91.5 cm)26-1/2”(67.3 cm)9–5/32”(23.3 cm)82–3/4”(210.2 cm)min.

Seite 20 - Front of unit

Specifications 924”(61.0 cm)35”(88.9 cm)75–15/16”(192.9 cm)3–19/32”(9.1 cm)36”36”(91.5 cm)(91.5 cm)36”(91.5 cm)26–1/2”(67.3 cm)9–5/32”(23.3 cm)82–3/4”

Seite 21 - Refrigerator

Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.Note: Top of unit must be placed firmly under anti-tip board. Anti-Tip LocationFlush

Seite 22 - Performance Checklist

Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.Note: Top of unit must be placed firmly under anti-tip board. 79–3/8”(201.6 cm) min.

Seite 23 - Verify Operations

24”(61.0 cm)1”(2.54 cm)Between Units35”(88.9 cm)36”36”(91.5 cm)(91.5 cm)36”(91.5 cm)9–5/32”(23.3 cm)82–3/4”(210.2 cm)min.to84–1/16”(213.5 cm)max.20–3/

Seite 24

Specifications 1724”(61.0 cm)1”(2.54 cm)Between units35”(88.9 cm)35”(88.9 cm)36”36”(91.5 cm)(91.5 cm)36”(91.5 cm)36”36”(91.5 cm)(91.5 cm)36”(91.5 cm)9