Viking VCRB5303RSS Installationshandbuch

Stöbern Sie online oder laden Sie Installationshandbuch nach Kühlschränke Viking VCRB5303RSS herunter. Viking VCRB5303RSS Installation Instructions Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Installation Guide

Installation Guide5 SeriesAll Refrigerator/All Freezer

Seite 2 - Table of Contents

9”(22.9 cm)73–3/8”(186.4 cm)82–7/8”(210.5 cm) min.anti-tip board &opening height84–1/16”(213.5 cm) max.anti-tip board &opening height35–5/8”(9

Seite 3 - Please Read and Follow!

Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.Note: Top of unit must be placed firmly under anti-tip board. 79–3/8”(201.6 cm) min.

Seite 4

24”(61.0 cm)1”(2.54 cm)Between Units82–3/4”(210.2 cm)min.to84–1/16”(213.5 cm)max.20–3/4”(52.7 cm)22–3/16”(56.4 cm)75–15/16”(192 .9 cm)3–19/32”(9.1 cm)

Seite 5

24”(61.0 cm)1”(2.54 cm)Between Units82–3/4”(210.2 cm)min.to84–1/16”(213.5 cm)max.20–3/4”(52.7 cm)22–3/16”(56.4 cm)75–15/16”(192 .9 cm)3–19/32”(9.1 cm)

Seite 6 - 75–15/16”

24”(61.0 cm)1”(2.54 cm)Between Units82–3/4”(210.2 cm)min.to84–1/16”(213.5 cm)max.20–3/4”(52.7 cm)22–3/16”(56.4 cm)75–15/16”(192 .9 cm)3–19/32”(9.1 cm)

Seite 7

15Dual All Refrigerator/All Freezer* Description (2) 30” Units (1) 36” & (1) 30” Unit (2) 36” UnitsOverall width 60” (152.4 cm) 66” (167.6 cm)

Seite 8

24”(61.0 cm)1”(2.54 cm)Between Units82–3/4”(210.2 cm)min.to84–1/16”(213.5 cm)max.20–3/4”(52.7 cm)23–3/8”(59.4 cm)75–15/16”(192 .9 cm)3–19/32”(9.1 cm)2

Seite 9

1724”(61.0 cm)1”(2.54 cm)Between Units82–3/4”(210.2 cm)min.to84–1/16”(213.5 cm)max.20–3/4”(52.7 cm)23–3/8”(59.4 cm)75–15/16”(192 .9 cm)3–19/32”(9.1 cm

Seite 10 - Water Line Entry Area

24”(61.0 cm)1”(2.54 cm)Between Units82–3/4”(210.2 cm)min.to84–1/16”(213.5 cm)max.20–3/4”(52.7 cm)23–3/8”(59.4 cm)75–15/16”(192 .9 cm)3–19/32”(9.1 cm)3

Seite 11 - Anti-Tip Dimensions

19Dual All Refrigerator/All Freezer w/Flush Mount Trim*Description (2) 30” Units (1) 36” & (1) 30” Unit (2) 36” UnitsOverall width 60” (152.4 cm

Seite 12 - Dimensions

2Table of ContentsWarnings & Important Information_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Seite 13

9”(22.9 cm)73–3/8”(186.4 cm)82–7/8”(210.5 cm) min.anti-tip board &opening height84–1/16”(213.5 cm) max.anti-tip board &opening height59–5/8”(1

Seite 14

79–3/8”(201.6 cm) min.to bottom of anti-tip board80–1/2”(204.6 cm) max.to bottom of anti-tip boardOne 2”x 4” mounting board per unit1–1/2” (3.8 cm) x

Seite 15 - Specifications

9”(22.9 cm)73–3/8”(186.4 cm)82–7/8”(210.5 cm) min.anti-tip board &opening height84–1/16”(213.5 cm) max.anti-tip board &opening height65–5/8”(1

Seite 16

79–3/8”(201.6 cm) min.to bottom ofanti-tip board80–1/2”(204.6 cm) max.to bottom ofanti-tip boardNote: If unit is installed deeper than24” (61.0 cm), t

Seite 17

9”(22.9 cm)73–3/8”(186.4 cm)82–7/8”(210.5 cm) min.anti-tip board &opening height84–1/16”(213.5 cm) max.anti-tip board &opening height71–5/8”(1

Seite 18

79–3/8”(201.6 cm) min.to bottom ofanti-tip board80–1/2”(204.6 cm) max.to bottom ofanti-tip boardNote: If unit is installed deeper than24” (61.0 cm), t

Seite 19

Top ViewTop View1–13/16”(4.6 cm)Space if 24” (61.0 cm)standard cabinetdepth is usedDoor24”(61.0 cm) Standard cabinet depthWall3/

Seite 20 - Cutout Dimensions

Top View1–13/16”(4.6 cm)Space if 24” (61.0 cm)standard cabinetdepth is usedDoor24”(61.0 cm) Standard cabinet depthWall3/4”(1.9 cm

Seite 21

Top ViewTop ViewDoor24”(61.0 cm)Standard cabinet depth25”(63.5 cm)countertop depthWall3/4”(1.9 cm)Full end panel DoorWall1”(2.5 cm)space if25” (

Seite 22

Top ViewFlush mount cabinet doorsTop ViewOverlapping cabinet doorsDoor24”(61.0 cm)Standard cabinet depth24-3/4”(62.9 cm)Wall3/4”(1.9 cm)Full end panel

Seite 23

3IMPORTANT–Please Read and Follow!• Make sure that incoming voltage is the same as unit rating. An electric rating plate specifyingvoltage, frequency,

Seite 24

3/4”(1.9 cm)End panel5/32”(0.4 cm)3/16”(0.5 cm)Back fillerpanel22-7/16”(57.0 cm)22-7/16”(57.0 cm)22-1/4”(56.5 cm)6”(15.2 cm)Optional kickplate notchDi

Seite 25

3/4”(1.9 cm)End panel1”(2.5 cm)1/4”(0.6 cm)Z-Bracket21-3/4”(55.2 cm)21-3/4”(55.2 cm)24”(61.0 cm)Optional kickplate notchDimensions determined by cabin

Seite 26 - Top View

32Area RequirementsVerify the following:• Unit can fit into residence and can bemoved around corners and throughdoorways.• Floors can support unit’s w

Seite 27 - Cabinet Information

33Water Supply Requirements(All Freezer)Use only 1/4” (6 mm) copper tubing forwater line. Do Not install copper tubing inarea where temperatures drop

Seite 28 - (With Flush Mount Trim)

• Most of the unit’s weight is at the top.Extra care is needed when moving the unitto prevent tipping. • Do Not remove protective film until unit isin

Seite 29

3512Place unit in front of cutout.Pull the center grille louver up at an angle and pull out.34Using an 8” magnetic nut driver, remove the two 1/4” scr

Seite 30 - Custom Side Panel Dimensions

36Remove 4 side screws and remove unit top.Loosen the 4 hinge screws. Adjust door. Retighten 4 hinge screws.Replace unit top. Replace 4 side screws.At

Seite 31

3793”3”3”10aPlug in power cord to verify operation. Note: Make sure power switch and showroom switchare in the “On” Position.Place unit within 3” of b

Seite 32 - General Information

38Turn on water supply and check for leaks.Lift unit off rollers to desired height and level unit usinga 5/16” head wrench.Note: DO NOT use an electri

Seite 33

39312201221110˚120˚90˚Open refrigerator door so door stop and shoulder screw are accessible.Note: Shoulder screw should be in 110˚ door opening positi

Seite 34

24”(61.0 cm)35”(88.9 cm)75–15/16”(192.9 cm)3–19/32”(9.1 cm))36”36”(91.5 cm)(91.5 cm)36”(91.5 cm)26-1/2”(67.3 cm)9–5/32”(23.3 cm)82–3/4”(210.2 cm)min.t

Seite 35 - Installation

40Press “ACTIVATE CONTROLS” button pad and closedoor.Note: There is a 6 minute delay before the unit starts. 26

Seite 36 - Front of unit

41 Verify cabinet size. Verify electrical supply and watersupply (if applicable). Install anti-tip device(s) and verify unit issecure. Positio

Seite 37

42Control Panels1. Press “Activate Controls” pad.2. Verify unit is not in Sabbath Mode.If in Sabbath Mode:A. The Sabbath Mode will disable the inter

Seite 38 - Refrigerator

43Only authorized replacement parts may be used in performing service on the appliance. Do notrepair or replace any part of the appliance unless speci

Seite 39

Viking Range, LLC111 Front StreetGreenwood, Mississippi 38930 USA(662) 455-1200For product information,call 1-888-(845-4641)or visit our web site at v

Seite 40

530” All Refrigerator/All FreezerDescription VCFB/CVCFB VCRB/CVCRBOverall width 30” (76.2 cm)Overall height from bottom 82-3/4” (210.2 cm) min. to 84-

Seite 41 - Performance Checklist

24”(61.0 cm)35”(88.9 cm)75–15/16”(192.9 cm)3–19/32”(9.1 cm)36”36”(91.5 cm)(91.5 cm)36”(91.5 cm)26–1/2”(67.3 cm)9–5/32”(23.3 cm)82–3/4”(210.2 cm)min.to

Seite 42 - Verify Operations

730” All Refrigerator/All Freezer with Flush Mount TrimDescription VCFB/CVCFB Flush Mount VCRB/CVCRB Flush MountOverall width 30” (76.2 cm)Overall he

Seite 43 - Service & Registration

9”(22.9 cm)73–3/8”(186.4 cm)82–7/8”(210.5 cm) min.anti-tip board &opening height84–1/16”(213.5 cm) max.anti-tip board &opening height29–5/8”(7

Seite 44

Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.Note: Top of unit must be placed firmly under anti-tip board. Anti-Tip LocationFlush

Kommentare zu diesen Handbüchern

Keine Kommentare